Specification:
ZW32-12 type outdoor pole-mounted HV vacuum CB (hereinafter referred to as CB) is rated voltage12kV, 50Hz three-phase AC outdoor power distribution equipment used for power distribution network to break and close load current, over-load current and short-circuit current in electric systems. It is used in substation and industrial & mining enterprise power distribution system for protection and control, better fits countryside power grid and frequent operation places, especially for the retrofit of urban power network and countryside power network. Characteristic:
The CB applies three-phase pole-type structure. It has characteristics of stable closing/breaking property, no fire or explosion danger, maintenance-free, small dimension, small weight, long service life, etc.
CBS can be fitted with two-phase or three-phase current transformers for automatic over-current release and supplying circuit information for intelligent controller.
Weight of CB<100kg
Overall dimension: H× W× D 740x960x880 (with isolation) 720x900x240 (without isolation)
Items |
Unit |
ZW32-12/400 |
ZW32-12/630 |
ZW32-12/1250 |
|
Rated voltage |
kV |
12 |
|||
Rated current |
A |
400 |
630 |
1250 |
|
Rated short circuit breaking current |
kA |
20/25 |
|||
Rated short circuit making current (peak value) |
50 |
||||
Rated peak withstand current |
50 |
||||
Rated short circuit withstand current |
50 |
||||
Rated short circuit duration |
S |
4 |
|||
Rated insulating level |
1 minimum PF withstand voltage |
Phase to phase, to ground 40, fracture 48 |
|||
Lightning impolse withstand voltage peak value |
phase to phase, to ground 75, fracture 85 |
||||
Rated sequence of operations |
O-0.3s-CO-180s-CO |
||||
Rated short circuit current breaking time |
30 |
||||
Mechanical endurance |
10,000 |
||||
Rated operation voltage (opening, closing coil) |
V |
DC220,110 AC220,110 |
|||
Moving and fixed contact allowance wearing collation thickness |
mm |
3 |
|||
Over-current release nominal current |
5 |
||||
Current transformer ratio |
A |
200/5,400/5 and 600/5 |
|||
1 minimum second PF withstand voltage |
mm |
2 |
|||
Over current tripping current |
A |
5 |
|||
Rated single capacitor bank switching current |
kA |
630 |
http://www.tyouelectric.com/